United States
Acinterlab
Welcome to Acinterlab
0 Items $0.00 Cart

You have no items in your shopping cart.

Return to Previous Page

Scan® 4000 Ultra-HD colony counter - Interscience

Be the first to review this product

$23,300.00



Brand: Interscience
Part#: Scan® 4000

Details

Scan® 4000 Ultra-HD colony counter - Interscience

1. HIGH QUALITY.

  • •   Stainless steel body.
  • •   Ultra HD color camera.
  • •   Digital zoom x 64.
  • •   Resolution: 5 mega-pixels.
  • •   Counting: 1000 colonies per second.

2. THE LARGEST READING RANGE ON THE MARKET.

  • •   Round Petri dishes from ø 55 to ø 150 mm.
  • •   Square Petri dishes of 120 mm.
  • •   Chromogenic Petri dishes.
  • •   PetriFilmTM.
  • •    RIDATM Count.
  • •    Compact DryTM Count.
  • •    Filtration membranes
  • .

3. UNEQUALLED LIGHTING.

  • •   360° LED lighting, without reflection or shadow of the dish with White Dome.
  • •   CCD 5 megapixels camera, detects bare eye invisible details .
  • •   Beam Splitter to ensure lighting 100% without reflections or shadows .
  • •   Automatic detection of the dish + reading on 100% of the dish.

4. UNEQUALLED LIGHTING.

  • •   Rapid detection: up to 16 antibiotic sensitivities per dish in 1 click.
  • •   3 diffusion modes: paper disks (all brands), wells, peni-cylinders .
  • •   Inhibition zones and agar wells can be manually added or deleted.
  • •   Built-in antibiotic database: CA-SFM (French Society of Microbiology), EUCAST (European Committee on Antimicrobial Susceptibility Testing).
  • •   Reads on: Muller Hinton agar, blood agar, chocolate agar.
  • •   Accuracy of inhibition zone measurement: 0.1 mm.

5. FULL TRACEABILITY.

  • •   Harmonization of the results within a team.
  • •   Automatic archiving and printing of data: pictures, comments & results.
  • •   External traceability (Session saved, Excel™, PDF, JPEG, BMP, Scan® printed report).
  • •   Internal traceability (Barcode, file archive, LIMS connection).
  • •   Securization of the sessions (Compliance with CFR 21 part 11: system securization, operational controls and documentation management).

6. EXCELLENT REPRODUCIBILITY AND REPEATABILITY.

  • •   GLP (Good laboratory Practice).
  • •   In compliance with :
  • •   ISO 15189.
  • •   ISO 7218.
  • •   ISO 4833-2.
  • •   NF V08-034.
  • •   NF V08-100.
  • •   AOAC 977.27.
  • •   FDA-BAM standards.

FDA-BAM standards

Scan® automatic colony counters use an exclusive software developped by INTERSCIENCE: evolutive, user-friendly and powerful.

There are numerous advantages in using Scan® counting software:

  • •   Only one clic to count .
  • •   Only one setting cursor .
  • •   Traceability: automatic saving of data, Excel™ export.

To try the demo version with your samples, please identify below or register here

1. VISUALISATION WINDOW.
Detected colonies are highlighted and marked with a cross.

2. PARAMETERS WINDOW.
Only one cursor to optimize counting. customizable settings adaptable to any kind of agar.

3. RESULTS WINDOW.
All previously recorded data can be checked anytime.

EASY DATA EXPORT.
Scan® software provides easy ways to export quickly your results:

  • •   Human and Animal tissue, tumors, CA © natural or cultured cells.
  • •   Work sessions saving.
  • •   PDF export.
  • •   JPEG, BMP export.
  • •   Results exported to Excel™.
  • •    Scan® printed report.

EXAMPLE OF A SCAN® PRINTED REPORT
Check in a glance images before and after counting, complete sample information, comments and results.



  Scan® 4000
Reference 438 000
Camera Ultra HD CCD color camera
Lens Ultra HD japanese lens
Digital zoom x 69
Resolution 5 megapixels
Counting time 1000 colonies per second
Minimum size colony 0.05 mm
Lighting White LED dome
Lighting system Automatic: 7 combinations, top and/or bottom light white
or black background
Counting Automatic, with manual control
Counting on Petri dishes Square and round Petri dishes (55-150 mm)
Counting on pour, surface, Spiral® and circle plated dishes
Counting on chromogenic dishes
Inhibition zone reader
Inhibition zone measurement accuracy 0.1 mm
Reads on Muller Hinton agar, blood agar, chocolate agar
Counting on PetriFilm™
Counting on RIDA™ Count or NeoFilm™
Counting on Compact Dry™
Counting on filtration membranes
Automatic detection of paper disks, agar wells, peni-cylinders
Results /Data export Recountable Scan® session, PDF report, JPEG, PNG, BMP, Excel™
Color detection 7 colors on the same dish
LIMS/SIL connection
USB connection
Languages English, French, Japanese, Chinese, Russian, Spanish, German
Dimensions (w x d x h) 47 x 47 x 64 cm
Weight 25 kg
Voltage 100-240 V ∼ 50/60 Hz
Power 140 W
Processor Intel (Quad core recommended) Intel i5 or i7 or AMD FX 6000 and superior
Operating systems Windows™ 7 Service Pack 1 or Windows™ 8 or 10
Frequency 2.4 Ghz or superior
RAM 4 Go or better
Graphic card AMD or NVIDIA (chipsets are not recommended)
Equipment USB 2.0 port / CD-ROM reader
Screen 1280 X 1024 pixels and more
Computer Desktop computer recommended
Hardware Stainless steel
Software update (after registration) 3 years
Guarantee (after registration) 3 years
In compliance with GLP (Good laboratory Practice), CFR 21 part 11, ISO 15189, ISO 7218, ISO 4833-2, NF V08-034, NF V08-100, AOAC 977.27, FDA-BAM standards

PHARMACEUTICAL INDUSTRIES

- Sterile room monitoring
The Scan® 4000 enables the reading and recording of air samples for bacteriological control of sterile rooms.
With Scan ® 4000, you have complete traceability on your air quality. Your clients will be really satisfied about it!
The integrated management in the CFR part 11 V8 software enables more security and flexibility.

- Antibiotics efficiency measurement
During antibiotics manufacture, it is necessary to compare the efficiency of the antibiotic with a reference.
Scan® 4000 enables the reading of inhibition zones, with peni-cylinders, without peni-cylinders or agar well.


MEDICAL AND VETERINARY INDUSTRIES

- Antibiotics sensitivity
For bacteriological labs, hospitals and clinic, the use of Scan® 4000 reads up to 12 paper disks on round dishes and 16 paper disks on square dishes.
You can memorize your masks and analyze your dish in a few seconds.
The result of the sensitivity in contact with the antibiotic is quick and the visualization of the results is simple:
  • •   Red: resistant.
  • •   Yellow: intermediary.
  • •   Green: sensitive.

The color image of the Petri dish is HD.

FOOD INDUSTRIES

- Quality control
FFor food instries, during microbiological analyses, the counting step is capital.
Scan® 4000 count colonies with results’ export and guarantee of traceability on all media used in labs. Get instant results and traceability on Petri dishes (55-150 mm), Spiral® plated dishes, PetriFilm™, RIDA™ Count, Compact Dry™ and filtration membranes.

Additional Information

Brand Interscience

Write Your Own Review

You're reviewing: Scan® 4000 Ultra-HD colony counter - Interscience

Product Tags

Use spaces to separate tags. Use single quotes (') for phrases.